A VOC treatment system has to be matched to what is actually in the exhaust: which compounds, how concentrated, at what airflow and temperature. Nexus Turnkey supplies the AirMax air quality range as technology partner and authorised distributor, covering activated-carbon units and towers, zeolite rotor concentrators, regenerative thermal oxidisers, packed-bed, venturi and wet scrubbers, cartridge and bag dust collectors, cyclones, cleanroom equipment, odour control and monitoring. We characterise the exhaust first, then design, install and commission the system.

How to choose

Start from the duty, not the machine

Matching the technology to the pollutant
What is in the airUsual technologyWhere it fitsWatch for
VOCs at low concentration, modest airflowActivated-carbon units or towersPrinting, coating and small paint linesCarbon saturation; change-out cost
VOCs at low concentration, high airflowZeolite rotor concentrator, often followed by an oxidiserPaint shops, printing, coating, footwearPre-filtration to protect the rotor
VOCs at higher concentrationRegenerative thermal oxidiser (RTO)Coating, chemical and printing exhaustFuel use at low concentration; safety interlocks
Acid or alkaline gases, mists, odoursPacked-bed, venturi or wet scrubberChemical, plating, rendering and wastewaterScrubber liquor treatment and disposal
Dust and particulateCartridge or bag dust collector, cyclone pre-separatorCement, rice and feed mills, grinding, welding, woodExplosion risk with combustible dusts
Qualitative guidance. Final selection follows a site survey and your demand data.

Families

Air quality & emissions we supply and support

Ranges are indicative. Confirm against the current manufacturer datasheet.

Treat the exhaust you have, not a generic one

Two factories can both say they have a VOC problem and need completely different equipment. One prints packaging with a few solvents at high airflow and low concentration. Another runs a coating oven with a concentrated, hot exhaust. The technology that is economical for one is wasteful for the other. So we start by characterising the air: which compounds, at what concentration, at what airflow and temperature, with what dust or moisture alongside.

Nexus Turnkey is technology partner and authorised distributor for AirMax, and supplies its air quality and emissions range:

  1. TVOC control: activated-carbon filtration units and adsorption towers.
  2. Chemical scrubbers: packed bed for acid and alkaline gases, venturi for dust, mist and fumes, and wet scrubbers for odours and chemical gases.
  3. Zeolite rotor VOC concentrators with fans, PLC and HMI.
  4. Regenerative thermal oxidisers, fully automatic.
  5. Dust collection: cartridge collectors, bag filters and cyclones.
  6. Cleanroom and positive pressure: HEPA H13/H14, laminar flow units and pass boxes.
  7. Odour control: activated carbon, bio-filters and chemical scrubbers.
  8. Air quality monitoring and display.

How to choose: concentration, airflow and chemistry

The table above gives the first cut. In more detail:

  • Activated carbon adsorbs VOCs onto a very large internal surface. It is simple and works well at low concentrations. The carbon saturates and must be replaced or regenerated, so its running cost grows with the solvent load.
  • A zeolite rotor adsorbs VOCs from a large airflow, then desorbs them into a much smaller, hotter airflow. That concentrated stream is then destroyed, often in an oxidiser. Concentration makes large, dilute exhausts economical to treat.
  • An RTO oxidises VOCs at high temperature and recovers most of that heat in ceramic beds, so the incoming air is preheated. At high enough concentrations the VOCs supply much of the heat needed to keep it running.
  • Scrubbers absorb gases into a liquid, with chemistry chosen for the pollutant. They also capture mists and some particulates.
  • Dust collectors filter particulates from extraction air. Cyclones remove coarse material before the filter.

Each product page gives typical performance figures as indicative ranges. Actual performance depends on the application, and we state it for your exhaust after characterisation. The industrial air quality guide and our article on VOC control with activated carbon, zeolite and RTO go further.

What to consider in Cambodian plants

High ambient humidity matters here. Moist air competes with VOCs for space on activated carbon and can reduce its capacity, so humid exhausts may need conditioning first. Dust from cement, rice and feed handling is fine, abrasive and sometimes combustible, so collectors need the right media, cleaning system and explosion protection. Our article on dust collection for cement, rice and feed mills covers those cases.

What Nexus supplies and supports

We characterise the exhaust, select the AirMax technology, design the ducting, fans, controls and safety systems, then install and commission. Performance is measured at handover against the agreed design basis. After that we supply consumables such as carbon, filter cartridges and bags, and maintain the system under a planned contract. Monitoring can feed Nexus AirSight on our SCADA and monitoring page.

FAQ

Questions engineers ask us

Activated carbon, zeolite rotor or RTO: how do I choose?

By concentration and airflow. Activated carbon suits low concentrations at modest airflow. A zeolite rotor concentrates a large, dilute airflow into a small, rich one that is cheaper to destroy. An RTO destroys VOCs by oxidation and suits higher concentrations. Many plants use a rotor and an oxidiser together.

What removal efficiency can I expect?

It depends on the compounds, their concentration, the airflow and how the system is maintained. Typical figures are given on each product page as indicative only. We state an expected performance for your exhaust after we have characterised it.

Do we need to measure our emissions before you can propose a system?

We need to know what is in the exhaust. Solvent consumption records, safety data sheets and airflow measurements are often enough to start. For a firm design we may recommend sampling.

How do you handle combustible dust in a dust collector?

Combustible dusts such as flour, grain, wood and some powders can explode. We identify the risk at design stage and include the protection the application calls for, such as explosion venting, isolation and earthing, and keep ignition sources out of the collector.

Can you monitor air quality continuously?

Yes. Sensors for parameters such as particulates, TVOC, temperature and humidity can report to a local display or to Nexus AirSight, our monitoring overlay, so EHS and production see the same numbers.

Next step

Tell us what is leaving your stack

Send the process, the solvents or dusts involved and the exhaust fan details. We will tell you which technologies are worth evaluating.

Start typing to search