Toolkit · Leak cost calculator

Put a number on the air you are paying to lose

A compressed air leak cost calculator turns a count of leaks into air lost, power, energy and annual cost. This one uses the US Department of Energy method: number of leaks × leakage rate (cfm) × kW per cfm × hours × tariff. Leakage rates come from the DOE leak tip sheet table for 1/32 to 3/8 in holes at 70–125 psig, interpolated for your pressure and corrected for orifice shape. The tariff starts at EDC's published industrial rate at medium voltage (USD 0.137/kWh); replace it with your own and, if you have it, your measured specific power. Cost results include a 10 % service fee. The result is an estimate, not a survey: an ultrasonic leak survey measures what you actually have.

Your inputs

Units
Number of leaks by size

Equivalent hole diameter. A survey report or tag log gives you these counts.

bar g

The DOE table covers 70–125 psig (4.8–8.6 bar g). We interpolate between its rows.

h/yr

Leaks lose air whenever the system is under pressure, not only during production. 8,760 h is a full year; the DOE worked example uses 7,000 h.

USD/kWh

Prefilled with EDC's published industrial tariff at medium voltage (USD 0.137/kWh, Electricity Authority of Cambodia, 2024). Replace it with the all-in rate from your bill. Cost results include a 10 % service fee.

Assumptions you can change
kW/(m³/min)

Default: about 18 kW per 100 cfm (6.36 kW per m³/min), the US DOE worked-example value. Your own measured figure is better: an audit gives it.

Leak shape (orifice factor)

From the DOE table footnote. DOE's own worked example uses sharp-edged (×0.61), the more conservative choice.

Results

Results appear here when JavaScript is enabled.

—Estimated cost of leaks per year
Air lost
—m³/min
Also
—cfm
Power
—kW
Energy
—kWh/yr

By leak size

  • 1/32 in (0.8 mm) × 0—
  • 1/16 in (1.6 mm) × 0—
  • 1/8 in (3.2 mm) × 0—
  • 1/4 in (6.4 mm) × 0—
  • 3/8 in (9.5 mm) × 0—

Carry these results into a quote

How it's calculated

The US Department of Energy's leak tip sheet gives the cost of leaks as:

cost (USD/yr) = Σ [ number of leaks × leakage rate (cfm) × kW per cfm × hours per year × USD per kWh ]

The leakage rate per hole comes from DOE's table of leakage for approximately equivalent orifice sizes, reproduced below. Between the listed pressures we interpolate in a straight line; we don't extrapolate beyond 70–125 psig. The table values are multiplied by the orifice factor in its footnote: 0.61 for sharp-edged holes, 0.97 for well-rounded ones.

Leakage rates (cfm) before the orifice factor. Source: US DOE Compressed Air Tip Sheet #3, 2004
Pressure1/32 in1/16 in1/8 in1/4 in3/8 in
70 psig (4.83 bar)1.164.6618.6274.4167.8
80 psig (5.52 bar)1.265.2420.7683.1187.2
90 psig (6.21 bar)1.465.7223.192206.6
100 psig (6.89 bar)1.556.3125.22100.9227
125 psig (8.62 bar)1.947.6630.65122.2275.5
  • Air lost in m³/min = cfm × 0.028 317 (1 ft³ = 0.028 316 846 592 m³, exact).
  • kW = cfm × specific power. kWh/yr = kW × hours. Cost = kWh × tariff.
  • Check: DOE's worked example (100 leaks of 1/32 in at 90 psig, sharp-edged, 18 kW/100 cfm, 7,000 h, USD 0.05/kWh) gives USD 5,611 per year for that class, and this calculator returns the same.

Sources

  1. US DOE, Minimize Compressed Air Leaks, Compressed Air Tip Sheet #3 (DOE/GO-102004-1964, revised August 2004) (opens in a new tab)Cost formula, leakage-rate table (70–125 psig, 1/64–3/8 in), orifice factors 0.61 (sharp) and 0.97 (well-rounded), and the ≈18 kW/100 cfm worked-example value. Table credited to the Compressed Air Challenge.
  2. US DOE / Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry (DOE/GO-102003-1822, November 2003), section 3: Compressed Air System Leaks (opens in a new tab)Leak testing methods and why measured site data beats estimates; leak rates of 20–30 % of output in poorly maintained systems.

Results are estimates. They are only as good as the inputs and the published rules of thumb behind them, and they are not a quotation or a guarantee of savings. Leak sizes are equivalent orifice diameters, which is how ultrasonic surveys usually report them. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.

What the calculator does

Every leak in a compressed air system is a small hole that the compressor keeps feeding while the system is under pressure. This calculator estimates how much air those holes release, how much compressor power that takes, and what it costs you over a year.

It follows the method published by the US Department of Energy in its leak tip sheet:

cost = number of leaks × leakage rate (cfm) × kW per cfm × hours per year × tariff

The leakage rate for each hole size is read from the DOE table at your line pressure. The table values are then multiplied by an orifice factor. Real leaks are not perfect holes, so the factor matters, and the calculator lets you choose it.

How to use it

  1. Count your leaks by size. Enter the number of leaks in each class: 1/32, 1/16, 1/8, 1/4 and 3/8 in, shown with millimetre equivalents. These are equivalent hole diameters, which is how an ultrasonic leak detection survey usually reports them. If you have only a rough idea, start small and test a range.
  2. Enter line pressure. Use the pressure in the pipework where the leaks are, in bar g or psig. The DOE table runs from 70 to 125 psig (about 4.8 to 8.6 bar g). The calculator won’t extrapolate outside that range.
  3. Enter pressurised hours. Leaks lose air whenever the system is pressurised, including breaks, nights and weekends if compressors stay on. A full year is 8,760 hours.
  4. Enter your tariff. Use the all-in rate per kWh from a recent bill. We don’t prefill one.
  5. Check the assumptions. Under “Assumptions you can change” you can set specific power (default about 18 kW per 100 cfm, the DOE worked-example figure) and the orifice factor.

Results update as you type. Share the link to send the same inputs to a colleague, or print the page for a maintenance meeting.

How to read the results

  • Air lost is shown in m³/min and in cfm. Compare it with your compressors’ rated free air delivery: if leaks account for a large share, a compressor may be running just to feed them.
  • Power is the compressor input power needed to make that air, at your specific power.
  • Energy is power × hours, in kWh per year.
  • Cost per year is energy × tariff.
  • By leak size shows each class as a bar. Large holes dominate quickly, because leakage grows with the square of the diameter. In the DOE’s own example, ten 1/4 in leaks account for most of the total cost. Fix the biggest first.

Limits you should know

  • The DOE table assumes approximately equivalent orifices. A cracked hose or a worn coupling isn’t a neat hole, which is why the orifice factor is a choice, not a fact.
  • Specific power varies widely between compressors, control modes and load. The 18 kW per 100 cfm default is a worked-example value, not your plant’s number.
  • The calculator assumes leaks flow at full line pressure for all the hours you enter. If pressure drops when production stops, the real loss is lower.
  • Fixing leaks only saves energy if the compressor controls respond to the lower demand. The DOE tip sheet makes the same point: after repairs, re-check the supply side.

Estimates are a starting point. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.

When to call for a measured survey

Use this calculator to decide whether leaks are worth a closer look. If the number matters, measure it:

  • A leak detection survey finds, tags and sizes each leak while the plant runs, and builds a costed leak register.
  • An air audit logs power, pressure and flow, so the specific power and your system’s leak rate come from measurement, not from a table.
  • A maintenance contract keeps leaks from creeping back.

Related reading: the hidden cost of compressed air leaks and our compressed air guide. To see what a lower set pressure is worth, try the pressure reduction savings tool.

FAQ

Questions engineers ask us

Where do the leakage rates come from?

From the leakage table in the US Department of Energy's Compressed Air Tip Sheet #3 (revised 2004), which gives flow in cfm for holes from 1/64 to 3/8 in at 70, 80, 90, 100 and 125 psig. We interpolate in a straight line between those pressures and multiply by the orifice factor from the table's footnote.

Why is the default orifice factor 0.61?

The DOE footnote says to multiply the table values by 0.97 for well-rounded orifices and by 0.61 for sharp ones, and the tip sheet's own worked example uses 0.61. Real leaks vary, so you can switch to 0.97 or to the raw table values to see the range.

Is 18 kW per 100 cfm right for my compressors?

It is the value the DOE tip sheet uses in its worked example, so treat it as a starting point. Your compressors' real specific power depends on type, age, control mode and load. A measured air audit gives you the actual figure, and you can type it in.

Can I use bar instead of psi?

Yes. Switch to metric and enter line pressure in bar g; the calculator converts to psig to read the DOE table and shows air lost in m³/min as well as cfm. The table covers 70–125 psig, which is about 4.8–8.6 bar g.

Which electricity tariff does the calculator use?

It starts with EDC's general tariff for industrial and agricultural consumers connected at medium voltage, USD 0.137/kWh, as published by the Electricity Authority of Cambodia (Report on Power Sector 2024). Your own bill is better: replace it with your all-in rate. Cost results include a 10 % service fee, shown under the total. Without a tariff the calculator still shows air, power and kWh lost.

Next step

Want measured numbers instead of estimates?

We log your compressors and demand, then rank the actions by verified kWh.

Start typing to search