What the calculator does
Every leak in a compressed air system is a small hole that the compressor keeps feeding while the system is under pressure. This calculator estimates how much air those holes release, how much compressor power that takes, and what it costs you over a year.
It follows the method published by the US Department of Energy in its leak tip sheet:
cost = number of leaks × leakage rate (cfm) × kW per cfm × hours per year × tariff
The leakage rate for each hole size is read from the DOE table at your line pressure. The table values are then multiplied by an orifice factor. Real leaks are not perfect holes, so the factor matters, and the calculator lets you choose it.
How to use it
- Count your leaks by size. Enter the number of leaks in each class: 1/32, 1/16, 1/8, 1/4 and 3/8 in, shown with millimetre equivalents. These are equivalent hole diameters, which is how an ultrasonic leak detection survey usually reports them. If you have only a rough idea, start small and test a range.
- Enter line pressure. Use the pressure in the pipework where the leaks are, in bar g or psig. The DOE table runs from 70 to 125 psig (about 4.8 to 8.6 bar g). The calculator won’t extrapolate outside that range.
- Enter pressurised hours. Leaks lose air whenever the system is pressurised, including breaks, nights and weekends if compressors stay on. A full year is 8,760 hours.
- Enter your tariff. Use the all-in rate per kWh from a recent bill. We don’t prefill one.
- Check the assumptions. Under “Assumptions you can change” you can set specific power (default about 18 kW per 100 cfm, the DOE worked-example figure) and the orifice factor.
Results update as you type. Share the link to send the same inputs to a colleague, or print the page for a maintenance meeting.
How to read the results
- Air lost is shown in m³/min and in cfm. Compare it with your compressors’ rated free air delivery: if leaks account for a large share, a compressor may be running just to feed them.
- Power is the compressor input power needed to make that air, at your specific power.
- Energy is power × hours, in kWh per year.
- Cost per year is energy × tariff.
- By leak size shows each class as a bar. Large holes dominate quickly, because leakage grows with the square of the diameter. In the DOE’s own example, ten 1/4 in leaks account for most of the total cost. Fix the biggest first.
Limits you should know
- The DOE table assumes approximately equivalent orifices. A cracked hose or a worn coupling isn’t a neat hole, which is why the orifice factor is a choice, not a fact.
- Specific power varies widely between compressors, control modes and load. The 18 kW per 100 cfm default is a worked-example value, not your plant’s number.
- The calculator assumes leaks flow at full line pressure for all the hours you enter. If pressure drops when production stops, the real loss is lower.
- Fixing leaks only saves energy if the compressor controls respond to the lower demand. The DOE tip sheet makes the same point: after repairs, re-check the supply side.
Estimates are a starting point. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.
When to call for a measured survey
Use this calculator to decide whether leaks are worth a closer look. If the number matters, measure it:
- A leak detection survey finds, tags and sizes each leak while the plant runs, and builds a costed leak register.
- An air audit logs power, pressure and flow, so the specific power and your system’s leak rate come from measurement, not from a table.
- A maintenance contract keeps leaks from creeping back.
Related reading: the hidden cost of compressed air leaks and our compressed air guide. To see what a lower set pressure is worth, try the pressure reduction savings tool.