Solutions
Seven systems. One accountable team.
Nexus Turnkey engineers complete industrial air systems in Cambodia: compressed air, air quality and emissions, humidity control, HVAC and cooling, energy optimisation, live-plant renovation and SCADA monitoring, each designed, supplied, installed and supported by one accountable team.
- 01Compressed air systemsCompressed air system design at Nexus Turnkey covers the whole chain: generation, treatment, storage and condensate, distribution, power and automation, and the compressor room itself. We size each package from your measured or projected demand, treat air only to the ISO 8573-1 class your process needs, build in N+1 redundancy where downtime is costly, and ventilate the room for tropical heat. One team designs, supplies, installs, commissions and supports it, so one team answers for pressure, air quality and energy.Explore
- 02Air quality and emissionsIndustrial air pollution control in Cambodia starts with characterising what leaves your process: VOCs, dust, acid gases, odour or fumes, at what flow, temperature and concentration. Nexus Turnkey then designs capture at the source, selects the treatment technology that fits the stream (activated carbon, zeolite concentrators, RTOs, scrubbers, dust collectors or cleanroom filtration), and adds monitoring so you can see performance. We supply the AirMax range as technology partner and authorised distributor, and one team answers for the result.Explore
- 03Humidity controlIndustrial humidity control keeps moisture in production areas, warehouses and clean spaces at the level your product and process need, despite tropical outdoor air that stays warm and humid all year. Nexus Turnkey defines the target condition, calculates the moisture load, tightens the envelope, then selects refrigerant or desiccant-rotor dehumidification from the AirMax range and integrates it with your cooling and ventilation. Sensors and data logging show the condition is held, shift after shift.Explore
- 04HVAC and coolingIndustrial HVAC in Cambodia has to remove heat from processes, machines and people in an ambient that stays hot all year. Nexus Turnkey calculates the real cooling and ventilation load, then designs the plant around it: chillers, air handling units, cooling towers, ventilation fans or evaporative coolers from the Nexus range, with redundancy where cooling is critical and controls that run efficiently at part load. We install, commission and maintain it, so one team answers for temperature, uptime and running cost.Explore
- 05Energy optimisationCompressed air energy saving means delivering the flow your plant needs at the lowest stable pressure, with as little unloaded running and leakage as possible. Nexus Turnkey measures your system first, then works through six levers: right-sizing the hall, variable speed where it fits, sequencing, pressure discipline, leak control and heat recovery. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.Explore
- 06Plant renovationA compressor room upgrade at Nexus Turnkey follows seven steps: a condition and energy baseline, a keep-or-replace decision for every machine, a changeover plan that keeps production running, re-piping from dead-end lines to looped mains, treatment upgraded to the ISO 8573-1 class actually needed, a control overlay so old and new machines run as one hall, and a documented handover. Machines with useful life stay on as peak or standby units. Nothing is replaced just because it is old.Explore
- 07SCADA and monitoringNexus AirSight is a compressed air monitoring system and utilities SCADA overlay. It connects the compressors, dryers, meters and air quality sensors you already have, sequences the compressors as one hall, and shows flow, pressure, dew point, specific energy and alarms on one screen, with history and reports. Each machine keeps its own controller and protections; AirSight coordinates and records. It works with mixed brands and ages, using Modbus, EtherNet/IP, PROFINET or hardwired I/O.Explore
Engineering deliverables
What you receive, before you commit
Every stage ends in a document you can check, approve and keep. These sheets are generic samples of the format.
- SamplePID-02Rev ANexus Turnkey
P&ID excerptGeneration, treatment and storage with instrument tags, isolation and condensate routes. - SampleISO-03Rev ANexus Turnkey
Piping isometricRing main and drops with sizes, slopes, drain points and isolation valves. - SampleAUD-01Rev ANexus Turnkey
Air audit reportBaseline, demand profile, ranked actions with investment and payback assumptions, verification plan. - SampleCOM-04Rev ANexus Turnkey
Commissioning checklistPre-start, functional and performance checks, signed line by line. - SampleSAT-05Rev ANexus Turnkey
SAT certificateSite acceptance against agreed criteria, punch list and sign-off.
Next step
Not sure which solution fits?
Describe the problem in plain words. We'll tell you which systems are involved and what we'd measure first.