Make a large, dilute exhaust small enough to treat
Paint shops, printing halls and coating lines often extract a very large volume of air carrying a low concentration of solvent. Destroying VOCs directly in that whole airflow means heating all of it, which is expensive. A zeolite rotor concentrator adsorbs the VOCs from the large airflow and releases them into a much smaller one. That small, concentrated stream can then be destroyed economically, usually in an oxidiser.
AirMax zeolite rotor concentrators include the rotor, supply and exhaust fans, and PLC and HMI control. Typical VOC removal is in the region of 95 to 99 %, depending on the compounds, concentration and system design. We state expected performance for your exhaust after characterisation.
How it works
A slowly turning honeycomb rotor coated with hydrophobic zeolite sits across the exhaust. The rotor face is divided into zones:
- Adsorption zone: the main exhaust passes through and VOCs adsorb onto the zeolite. Clean air goes to the stack.
- Desorption zone: a small flow of heated air passes through, releasing the VOCs into a concentrated stream.
- Cooling zone: the rotor cools before it returns to adsorption.
The concentrated stream goes to a destruction stage, often a regenerative thermal oxidiser, which is much smaller than one sized for the full airflow. Heat from the oxidiser can supply the desorption air.
Where it fits
- Paint shops and spray lines.
- Printing and laminating.
- Footwear production, with its adhesives and solvents.
- Chemical and coating processes with large, dilute exhausts.
Selection notes
- Pre-filtration is essential. Paint overspray, dust and sticky aerosols coat the rotor. Multi-stage filtration upstream protects it.
- Know the compounds. Some high-boiling or polymerising compounds are difficult to desorb. We check the solvent list before design.
- Humidity. Hydrophobic zeolite is chosen to perform in humid air, which suits Cambodian conditions, but humidity is still part of the design data.
- Controls and safety. Concentrated streams must stay well below flammable limits. Interlocks and monitoring are part of the system.
What Nexus provides
Exhaust characterisation, system design with pre-filtration, rotor, oxidiser, ducting and controls, installation and commissioning with performance testing, and planned maintenance including filter changes and rotor inspection.