Phnom Penh, serving Cambodia and the region

Toolkit · Unit converter

Convert the units, then check you are comparing the same air

This compressed air unit converter converts flow (cfm, m³/min, m³/h, L/s), pressure (bar, psi, kPa, MPa, gauge and absolute), power (kW, hp) and temperature (°C, °F, K) using factors derived from exact definitions listed by NIST. 100 cfm is 2.8317 m³/min, 1 bar is 14.504 psi and 1 hp is 0.7457 kW. It changes units only: free air delivery, normal cubic metres and ISO 8573-1 reference volumes are measured at different conditions, and gauge pressure differs from absolute by the atmosphere. Notes on each, and on pressure dew point, sit beside the converter.

Your inputs

Quantity

Converted values

Results appear here when JavaScript is enabled.

Flow
UnitValue

Ask an engineer about these figures

Factors and the notes that matter

  • 1 ft³ = 0.3048³ m³ = 0.0283168466 m³ exactly, so 100 cfm = 2.83168 m³/min. 1 m³/min = 60 m³/h = 16.667 L/s.
  • 1 psi = 6.89475729 kPa; 1 bar = 100 kPa = 0.1 MPa exactly; 1 bar = 14.5038 psi.
  • 1 hp (mechanical, 550 ft·lbf/s) = 0.7456999 kW. Metric horsepower (PS) is slightly smaller and is not used here.
  • °F = °C × 9/5 + 32; K = °C + 273.15. A temperature difference of 1 K equals 1 °C and 1.8 °F.

Flow: free air, normal and standard volumes are not the same cubic metre

This converter changes units only. A cubic metre of air means different amounts of air depending on the reference conditions it is quoted at:

  • FAD (free air delivery): compressor output measured to ISO 1217, expressed at the compressor's inlet conditions. It is what a compressor datasheet quotes.
  • Normal cubic metres (Nm³): commonly 0 °C and 1.01325 bar absolute, dry (DIN 1343), though some suppliers use other references. Common for gas and nitrogen flows. Check the datasheet's definition.
  • ISO 8573-1 reference conditions: 20 °C, 100 kPa absolute, 0 % relative water vapour pressure. Purity limits are stated per cubic metre at these conditions.
  • "Standard" cfm (scfm) has several definitions in use. Ask which one before comparing two quotations.

Converting between these needs temperature, pressure and humidity, which is why we leave it to an engineer rather than a single factor.

Pressure: gauge or absolute

Plant pressures are almost always gauge (bar g, psig): pressure above the local atmosphere. Absolute pressure (bar a, psia) adds the atmosphere, about 1.013 bar at sea level and less at altitude. Compression ratios, dew-point calculations and gas laws need absolute pressure.

Dew point notes

  • Pressure dew point is the temperature at which water condenses at line pressure. It is the figure that matters for compressed air and the one ISO 8573-1 water classes 1–6 use.
  • Atmospheric dew point is the same air expanded to atmospheric pressure. It is always lower than the pressure dew point, so never compare the two directly.
  • The US DOE / CAC sourcebook quotes refrigerant-type dryers at a pressure dew point of 35–39 °F (about 2–4 °C) and twin-tower desiccant dryers typically at −40 °F (−40 °C).
  • Water stays out of your lines only while the air stays warmer than its pressure dew point. See the ISO 8573-1 class explorer for the water classes.

Sources

  1. NIST Special Publication 811 (2008), Guide for the Use of the SI, Appendix B.8: conversion factors (opens in a new tab)bar and standard atmosphere are exact; ft, in, lbf and hp factors derive from the exact definitions of the foot (0.3048 m) and pound-force.
  2. ISO 8573-1:2010 Compressed air, Part 1: Contaminants and purity classes, Clause 4 (reference conditions) (opens in a new tab)Reference conditions for gas volumes: 20 °C, 100 kPa absolute, 0 relative water vapour pressure.
  3. US DOE / Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry (2003) (opens in a new tab)Dryer pressure dew points: refrigerant-type 35–39 °F (about 2–4 °C); twin-tower desiccant typically rated at −40 °F (−40 °C).

Results are estimates. They are only as good as the inputs and the published rules of thumb behind them, and they are not a quotation or a guarantee of savings. Conversions are exact to the digits shown; what the numbers mean (free air, normal or standard volume; gauge or absolute pressure) is up to the datasheet you took them from. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.

What the converter does

Compressor and dryer datasheets mix units: cfm and m³/min, psig and bar g, hp and kW. Quotations from two suppliers can look different when they are the same machine, or the same when they are not. This converter handles the arithmetic and, more importantly, flags the cases where a unit conversion is not enough.

It covers four quantities:

Quantity Units
Flow cfm, m³/min, m³/h, L/s
Pressure bar, psi, kPa, MPa (gauge and absolute)
Power kW, hp
Temperature °C, °F, K

Every factor comes from exact definitions listed in NIST Special Publication 811: the foot is exactly 0.3048 m, the bar exactly 100 kPa, and the pound-force and horsepower are defined exactly from those. We carry full precision and round only for display.

How to use it

  1. Choose the quantity: flow, pressure, power or temperature.
  2. Type the value and pick the unit it is in. Every other unit updates as you type.
  3. For pressure, say whether your value is gauge or absolute. The default atmosphere is the standard 101.325 kPa; enter your local barometric reading for site work.
  4. Share the link to send the same conversion to someone else.

How to read the results

Flow: same unit, different air

A cubic metre is only comparable with another cubic metre at the same reference conditions:

  • FAD (free air delivery) is compressor output measured to ISO 1217 and stated at inlet conditions. It is what compressor datasheets quote.
  • Normal cubic metres are corrected to a reference temperature and pressure, commonly 0 °C and 1.01325 bar absolute, dry. Nitrogen and gas flows are often stated this way.
  • ISO 8573-1 states purity per cubic metre at 20 °C, 100 kPa absolute and zero humidity.
  • scfm has several definitions in use.

The converter changes units, not reference conditions. Correcting between them needs temperature, pressure and humidity, which is engineering work, not a factor. For more on cfm and m³/h, see the glossary.

Pressure: gauge or absolute

Plant gauges read pressure above atmosphere (bar g, psig). Absolute pressure adds the atmosphere, about 1.013 bar at sea level. Compression ratios, gas laws and dew-point calculations need absolute values.

Dew point

Pressure dew point is the temperature at which water condenses at line pressure, and it is the figure ISO 8573-1 water classes 1—6 use. Atmospheric dew point is always lower for the same air, so the two must never be compared directly. The US DOE / CAC sourcebook quotes refrigerant-type dryers at 35—39 °F (about 2—4 °C) pressure dew point and twin-tower desiccant dryers typically at −40 °F (−40 °C).

Limits you should know

  • Conversions are exact to the digits shown. What a number means depends on the datasheet you took it from.
  • Horsepower here is mechanical horsepower. Electrical input power is higher than shaft power by the motor losses.
  • Temperature differences convert differently from temperatures: a 10 K difference is 18 °F, not 50 °F.

When to call an engineer

If you are comparing compressor quotations, sizing a nitrogen generator from a gas flow in Nm³/h, or checking a dryer against a dew-point requirement, the reference conditions matter more than the units. Our design and engineering team can put competing offers on the same basis, and an air audit measures flow and dew point on your system. See also how to choose an air compressor and the compressed air guide.

FAQ

Questions engineers ask us

How many m³/min is 100 cfm?

100 cfm is 2.8317 m³/min, or about 169.9 m³/h. One cubic foot is exactly 0.3048³ m³, which is 0.028316846592 m³.

How many psi is 7 bar?

7 bar is 101.53 psi. One psi is about 6.8948 kPa and one bar is exactly 100 kPa. If the 7 bar is a gauge reading, it is about 8.01 bar absolute at standard atmospheric pressure.

Is cfm the same as scfm or Nm³/h?

No. cfm is a unit of volume per minute. scfm and Nm³/h are volumes corrected to stated reference conditions, and several definitions are in use. Converting between them needs temperature, pressure and humidity, not a single factor, so check the definition on each datasheet.

What is the difference between pressure dew point and atmospheric dew point?

Pressure dew point is the temperature at which water condenses at line pressure, and it is the figure that matters for compressed air. Atmospheric dew point is for the same air expanded to atmospheric pressure, and it is always lower. Never compare one with the other.

Which horsepower does the converter use?

Mechanical horsepower, 550 ft·lbf/s, which is 0.7457 kW. Metric horsepower is slightly smaller and is not used here.

Next step

Want measured numbers instead of estimates?

We log your compressors and demand, then rank the actions by verified kWh.