An industrial dehumidifier in Cambodia has to remove a heavy, constant moisture load, so it must be sized to the room, the processes in it and the humidity you need to hold. Nexus Turnkey supplies the AirMax range as technology partner and authorised distributor: portable, commercial, ducted, ceiling-mounted, swimming pool, desiccant rotor and low-temperature units. We calculate the moisture load, choose refrigerant or desiccant technology for the target condition, then install, commission and maintain the system.

How to choose

Start from the duty, not the machine

Choosing dehumidifier technology
Your space and targetUsual technologyWhyWatch for
Warm room, moderate humidity target (warehouse, garment store)Refrigerant: commercial, ducted or ceiling-mountedEfficient when the air is warm and humidDoor openings and infiltration drive the real load
Low humidity target, or air that must be very dryDesiccant rotorKeeps removing moisture where refrigerant coils cannotRegeneration heat is part of the running cost
Cool or cold room (cold stores, chilled production)Low-temperature or desiccant unitsStandard refrigerant coils ice up in cold airDefrost strategy and drain routing
Temporary problem, construction drying, or a trialPortable unitsFast to deploy and moveCondensate removal and electrical supply
Indoor pool hallSwimming pool dehumidifierBuilt for warm, chlorinated, very humid airCorrosion protection and ductwork
Qualitative guidance. Final selection follows a site survey and your demand data.

Humidity is a load, and it can be calculated

In a tropical climate, moisture arrives in a building all day and all year. It comes in with outside air, through doors and gaps, from people, from wet processes and from the products themselves. If the humidity in a room matters, for stored garments and fabric, packaged food, medicines, electronics or paper, then the relative humidity has to be held by equipment sized to that moisture load.

Nexus Turnkey is technology partner and authorised distributor for AirMax, and supplies the AirMax dehumidifier range:

  • Portable units for temporary or local problems.
  • Commercial units for rooms and stores.
  • Ducted units for larger spaces and air distribution.
  • Ceiling-mounted units where floor space is needed for work.
  • Swimming pool units for indoor pool halls.
  • Desiccant rotor units for low humidity targets.
  • Low-temperature units for cool and cold rooms.

How to choose: technology first, then capacity

There are two ways to take water out of air. A refrigerant dehumidifier cools air over a coil below its dew point, so water condenses and drains away, then reheats the air. It is efficient when the air is warm and humid. A desiccant dehumidifier passes air through a slowly turning rotor that adsorbs water vapour; a separate heated air stream regenerates the rotor and carries the water outside. It keeps working at low temperatures and low humidity targets where a cold coil would freeze or stop condensing.

Once the technology is right, capacity follows from the moisture load and the target. We estimate infiltration, door openings, ventilation air, occupants and process moisture, then select units and air distribution so the whole space reaches the target, not just the corner nearest the unit. The industrial dehumidification guide explains the method in more depth.

What to consider in Cambodian buildings

The outside air is the dominant moisture source for most of the year, and the monsoon season makes it worse. Three design points follow from that:

  • Seal before you size. Loading-bay doors, open roller shutters and unsealed roof gaps can let in more moisture than any reasonable dehumidifier removes. Strip curtains, fast doors and simple sealing are often the first recommendation.
  • Separate heat and moisture. Cooling systems in humid climates often leave humidity high at part load. A dedicated dehumidifier lets each system do one job well.
  • Plan the water. Condensate from refrigerant units and the wet regeneration air from desiccant units must be routed out of the building properly.

Our article on dehumidifiers for garment factories and warehouses covers the two most common cases we see, and humidity control in pharmaceutical and food plants covers stricter targets.

What Nexus supplies and supports

We survey the space, calculate the load, and propose the AirMax units, ductwork and controls to hold the target. We install and commission the system, verify humidity across the space at handover, and support it with filters, spare parts and planned maintenance. Where humidity and temperature both matter, we design it together with the HVAC and cooling system.

FAQ

Questions engineers ask us

Why not just use the air conditioning to control humidity?

Air conditioning is sized mainly to remove heat, not water. In humid weather it can bring a room to temperature while relative humidity stays high, especially at part load. Where humidity is the requirement, a dehumidifier sized to the moisture load does the job directly and lets the cooling system do its own.

Refrigerant or desiccant dehumidifier: which do I need?

Refrigerant units are usually the efficient choice in warm rooms with a moderate humidity target. Desiccant rotor units are the choice for low humidity targets, low temperatures, or where the air must be very dry, because they keep working where a cold coil cannot.

How do you size a dehumidifier?

From the moisture load: outside air and infiltration, door openings, people, wet processes and products that release moisture, against the humidity you need to hold. We survey the space and log temperature and humidity where it helps, rather than sizing by floor area alone.

Can dehumidifiers protect stored goods in a warehouse?

Yes. Many goods are damaged by sustained high humidity rather than by water: mould on textiles and paper, corrosion on metal parts, caking in powders. Holding the store below the humidity your goods tolerate prevents that. We help you set the target with your quality team.

What maintenance do industrial dehumidifiers need?

Filter cleaning or replacement, coil and drain inspection, and for desiccant units, checks on the rotor, seals and regeneration heater. We include them in planned maintenance alongside your other air systems.