Phnom Penh, serving Cambodia and the region

Solution

Every compressor, dryer and sensor on one screen, with one energy number

Nexus AirSight is a compressed air monitoring system and utilities SCADA overlay. It connects the compressors, dryers, meters and air quality sensors you already have, sequences the compressors as one hall, and shows flow, pressure, dew point, specific energy and alarms on one screen, with history and reports. Each machine keeps its own controller and protections; AirSight coordinates and records. It works with mixed brands and ages, using Modbus, EtherNet/IP, PROFINET or hardwired I/O.

Plant control room with operator desks and wall-mounted mimic panels

Nexus AirSight

See the whole hall. Run it as one.

A supervisory layer over the machines you already own: sequencing, alarms, trends and one energy number for the compressor hall. Toggle the control strategy to see how the sample picture changes.

AirSight · Hall 01 overview

Sample data · not from a live plant

Seeded simulation · 08:05:00Values change with the sample, not with any real plant

Sample picture, fixed-speed control without coordination: C1 runs loaded, C2 cycles between load and unload, and C3 idles unloaded, drawing power while making no air. Header pressure swings across a wide band of about 6.5 to 7.3 bar. Specific energy is about 0.14 kWh per normal cubic metre. Sample data, not from a live plant.

The problem: nobody can see the air

Ask most plants what a cubic metre of compressed air costs them and the answer is a guess. The compressors each have a controller, but the controllers do not talk to each other or to anyone else. Dryers alarm locally, if at all. Dew point is checked when something goes wrong. Air quality in production areas is measured once, for an audit, and then forgotten.

Without data, every decision is a debate. Is the new line why pressure is low, or is it leaks? Did last year’s upgrade actually save energy? Which compressor is due for service? Is the cleanroom holding its condition overnight? People argue from impressions because nobody has the numbers.

Our approach: an overlay, not a replacement

Nexus AirSight connects what you already have. It reads the compressors, dryers, meters and sensors on site, coordinates the compressors as one hall, and puts the results on one screen. The sample dashboard above shows the idea: machine tiles, flow, pressure, specific energy, dew point, alarms and trends. The figures in it are labelled sample data, and the toggle shows how a sequenced hall behaves differently from machines running on their own settings.

Machine logic stays at the machine. Each compressor keeps its own controller and every protection its manufacturer built in. AirSight adds sequencing, visibility and one energy number for the hall. It does not take away a single safety function.

Architecture, layer by layer

The scope table on this page sets out the five layers. In plain terms:

  1. Machine controllers keep each compressor, dryer and blower running safely.
  2. A sequencer decides which compressors run and in which order, holding the hall within one tight pressure band.
  3. A PLC and gateway collect signals from machines, power and flow meters and sensors, and convert between protocols.
  4. SCADA and a historian show live values, raise alarms and store history.
  5. The plant overlay turns that into dashboards and reports that owners, engineers and EHS can each use.

One hall. One pressure band. One energy number.

What AirSight does

Capabilities

  • Real-time monitoring of every connected machine, meter and sensor
  • Historical trends, so you can compare this week with last month, or before and after a change
  • Alarm management, with priorities and acknowledgement, instead of a local buzzer nobody hears
  • Reports and analytics, including specific energy (kWh/m³), unloaded hours and off-production demand
  • Remote access, set up to your IT policy, for managers and engineers off site

For compressed air, the core values are flow, pressure at the compressor room and at key points of use, pressure dew point, power, running and loaded hours, and specific energy. Those are the same KPIs we use for energy optimisation, so savings stay visible after a project ends.

Air quality monitoring

AirSight is not limited to compressed air. The same platform can show conditions in production areas, cleanrooms, warehouses and around emissions treatment equipment.

ParameterWhy it is monitored
PM2.5 and PM10Fine and coarse particulate in work areas and clean spaces
CO₂Ventilation adequacy in occupied spaces
TVOCSolvent vapours from printing, coating and chemical processes
Temperature and humidityProduct storage, process conditions and worker comfort
Pressure and differential pressureRoom pressure cascades and filter loading
Air velocityLaminar flow units, hoods and duct performance
Filter statusChange filters on condition, not on a calendar

These sensors connect to the same PLC and SCADA layers, so production, engineering and EHS work from one set of numbers. See air quality and emissions and humidity control for the systems they watch over.

Protocols

AirSight speaks the protocols industrial equipment actually uses: Modbus (RTU and TCP), EtherNet/IP, PROFINET and hardwired digital and analogue I/O. Where a machine uses something else, a gateway converts it. We document every signal in an interface schedule so your team knows exactly what is connected and how.

Brownfield reality

Real compressor halls are mixed. Different brands, different ages, some machines with modern controllers and network ports, some with relay logic and a pressure switch. Some have communication options that were never fitted. Others were never designed to be connected at all.

That is why AirSight pairs naturally with plant renovation. Older machines with useful life stay on as peak or standby units, coordinated by the same sequencer as the new ones.

How this fits with products and services

AirSight sits on top of the compressed air system, whether we built it or not. New air compressors and air treatment can be specified with the communication options it needs. Design and engineering produces the control philosophy and interface schedule. Installation and commissioning includes logic and alarm testing before handover. An air audit is often the first step, because it shows which measurements matter most for your site.

Standards literacy

Scope

What's included

AirSight architecture, from machine to screen
LayerWhat it doesWhat we supply or integrate
1. Machine controllersRun each compressor, dryer or blower safely; keep all machine protectionsExisting controllers retained; communication cards or hardwired signals added where needed
2. SequencerDecides which compressors run, in which order, within one pressure bandMaster sequencer or PLC-based sequencing logic
3. PLC and gatewayCollects signals from machines, meters and sensors; converts protocolsPLC, I/O, protocol gateways, power and flow meters, dew-point, pressure and air quality sensors
4. SCADA and historianDisplays live values, raises alarms, stores historySCADA screens, alarm configuration, historian and reports
5. Plant overlayPuts utilities in context: one energy number, trends and reports for owners, engineers and EHSDashboards, scheduled reports and secure remote access to your IT policy

FAQ

Questions engineers ask us

Do we have to replace our compressors to use AirSight?

No. AirSight is an overlay. It connects to the machines you already have, whatever their brand or age. Machines with a communications interface connect directly. Older machines connect through hardwired signals and power metering.

Does AirSight override the compressor's own safety functions?

No. Each compressor keeps its own controller and all of its protections. The sequencer tells machines when to start, load, unload and stop within limits the machine itself enforces. If communication is lost, machines fall back to their local pressure settings.

Which protocols does AirSight support?

Modbus (RTU and TCP), EtherNet/IP, PROFINET and hardwired digital and analogue I/O. Where a machine uses another protocol, we use a gateway to convert it.

Can AirSight monitor air quality as well as compressed air?

Yes. It can display PM2.5 and PM10, CO₂, TVOC, temperature, humidity, pressure, air velocity, differential pressure and filter status from sensors in production areas, cleanrooms and around emissions treatment equipment.

Can we see the data remotely?

Yes, if you want to. Remote access is set up to your IT policy, typically read-only by default, so managers and engineers can check status, trends and alarms without being on site.

Is the dashboard on this page real data?

No. The dashboard on this page runs on clearly labelled sample data to show how AirSight presents a compressor hall. Your system's screens are configured to your machines, sensors and reports.

Next step

Put your plant air on one screen

List your compressors, dryers and any meters or sensors you already have. We will propose how to connect them and what AirSight would show.