Products · AirMax

Industrial air filters graded to the job, from coarse pre-filters to fine pocket filters

Industrial air filters protect people, products and equipment by removing particles from ventilation, process and exhaust air. Nexus Turnkey supplies the AirMax filter range as technology partner and authorised distributor: filter media rolls and pads, panel filters including washable, mesh, carbon and high-temperature types, and pocket filters in EN 779 classes. EN 779 has been superseded by ISO 16890, so we advise the equivalent ISO 16890 rating for each application and set replacement intervals from pressure-drop readings.

How to choose

Start from the duty, not the machine

Where each filter type usually sits
StageTypical filterWhat it protectsChange on
Coarse pre-filtrationPre-filter media or panel filters (G2–G4 under EN 779)Coils, fans and the finer filters downstreamPressure drop or visible loading
Fine filtration in ventilation and AHUsPocket filters (M5–F9 under EN 779)Occupied spaces and processes from fine dustFinal pressure drop set for the system
Paint booths and spray linesPaint-stop glass fibre floor media, ceiling mediaThe finish, the fan and the exhaustLoading and pressure drop
Odour and gaseous contaminantsActivated-carbon panels or mediaPeople and products from odours and some VOCsSaturation or odour breakthrough
Hot air streamsHigh-temperature panel filtersOvens, dryers and process airInspection interval for the duty
Qualitative guidance. Final selection follows a site survey and your demand data.

A filter is a maintenance plan, not a part number

Filters fail quietly. A loaded filter keeps the dust out but chokes the airflow, so fans use more energy and rooms lose pressure. A collapsed or badly fitted filter lets dust bypass straight to coils, products and lungs. The right filter is the one with the right class, fitted properly, and replaced at the right pressure drop.

Nexus Turnkey is technology partner and authorised distributor for AirMax, and supplies its filter range:

  • Filter media: pre-filter media in G2–G4 classes, paint-stop glass fibre, air-inlet media, activated-carbon media, spray-booth ceiling media and melt-blown media.
  • Panel filters: pre-filter panels, washable aluminium, nylon mesh, metal mesh, activated-carbon and high-temperature panels.
  • Pocket filters in the EN 779 classes M5, M6, F7, F8 and F9.
  • HEPA filters, supplied with our cleanroom equipment.

How to choose: class, airflow and the stage it sits in

Filtration works in stages. A coarse pre-filter takes the bulk of the dust and protects the finer filter after it, which costs more and should last longer. A fine pocket filter then removes the particles that matter for people and processes. Where gases or odours matter, an activated-carbon stage follows.

Size matters as much as class. A filter run above its rated airflow loses efficiency and loads faster. We check airflow through each bank, choose the class for the job and the area for the airflow, and fit differential-pressure indication so changes are made on condition.

Our article on air filter classes: EN 779, ISO 16890 and HEPA explains the classes and what they mean for selection.

What to consider in Cambodian plants

Dust loads can be heavy, from roads, construction, cement and agricultural processing, and the dry season adds more. Pre-filters do a lot of work here and protect the expensive stages behind them. In the wet season, humid air can make some media sag or encourage microbial growth in neglected filters, so frames, seals and change intervals matter. Where filters sit in AHUs serving production areas, a good pre-filter stage also keeps cooling coils clean, which protects their capacity.

What Nexus supplies and supports

We match filters to your existing housings or specify new banks, supply them on a planned schedule, and can change them as part of a maintenance contract. Send us your filter list with sizes, classes and quantities and we will match each one, advise ISO 16890 equivalents, and point out where a different class or interval would help.

FAQ

Questions engineers ask us

Is EN 779 still valid?

EN 779:2012 has been withdrawn and replaced by ISO 16890 for general ventilation filters. Many filters are still labelled with EN 779 classes such as G4, M5 or F7. Because the two standards test differently, there is no exact one-to-one conversion. We advise the ISO 16890 rating that suits each application.

How often should pocket filters be changed?

On pressure drop, not on the calendar alone. Each filter has a recommended final pressure drop. A differential-pressure gauge across the bank shows when it is reached. Dusty sites need more frequent changes; changing too early wastes filters, and changing too late wastes fan energy and risks bypass.

Are washable filters a good idea?

For coarse pre-filtration in the right application, yes. Washable aluminium and mesh panels suit greasy or heavy dust loads where frequent replacement would be costly. They need proper cleaning and drying before refitting, and they do not replace fine filtration.

Do you supply HEPA filters?

Yes, HEPA H13 and H14 are supplied with our cleanroom and positive-pressure equipment. See the cleanroom family in the air quality and emissions range.

Can you supply filters to fit our existing housings?

Usually. Send the dimensions, the class and a photo of the existing filter and frame. We confirm fit and class before ordering.

Next step

Send us your filter list

Sizes, classes, quantities and how often you change them. We will match each one and suggest where a different class or a planned change interval would help.