Clean air is a production input and a licence to operate
Air quality in a plant has three audiences. Workers breathe it, so solvent vapour, dust and fumes are an occupational health issue. Products are exposed to it, so particles, microbes and chemical vapours become a quality issue. And neighbours and regulators receive what leaves the stack, so emissions become a permit and reputation issue.
The engineering is different for each contaminant, but the logic is the same:
- Identify the contaminant and where it is generated.
- Capture it at source, with the smallest airflow that does the job.
- Treat it with the technology that matches its physical and chemical properties.
- Discharge or recirculate safely.
- Measure that the system performs, at commissioning and continuously.
This guide covers volatile organic compounds (VOCs), dust, odour, acid fumes, clean rooms and positive pressure, filtration classes and monitoring, and ends with how to scope a project. It links to deeper insights and to the products and services we offer under air quality and emissions.
Know the contaminant before you choose the equipment
Most failed air-pollution-control projects chose a technology before they understood the exhaust. A carbon unit installed on a high-concentration solvent stream saturates in days. A cartridge collector installed on sticky, humid dust blinds. A scrubber sized from a guessed airflow either cannot capture the fume or spends energy moving air it does not need.
| Contaminant | Typical sources | Main technologies |
|---|---|---|
| VOCs and solvents | Painting, coating, printing, adhesives, footwear, chemicals | Activated carbon, zeolite rotor plus oxidiser, RTO |
| Dust | Cement, grinding, rice, feed, flour, wood, welding | Cartridge collector, baghouse, cyclone |
| Odour | Food processing, rendering, wastewater, rubber | Activated carbon, biofilter, chemical scrubber |
| Acid and alkaline fumes | Plating, pickling, etching, laboratories, chemical processes | Packed bed scrubber, venturi scrubber, wet scrubber |
| Particles and microbes in critical spaces | Pharma, hospitals, laboratories, electronics | HEPA filtration, clean rooms, positive pressure |
Three measurements make most selections possible: airflow at the point of capture (in m³/h or CMH), concentration of the contaminant, and temperature and humidity of the exhaust. Add the compounds involved, taken from the safety data sheets of the materials used, and the operating hours. With those, the technology choice is usually clear.
Capture, ducts and fans: the half of the system people forget
Every treatment technology in this guide sits at the end of a chain: a hood or enclosure, a duct network, a fan and a stack. If the chain does not deliver the contaminant to the treatment unit, the unit’s efficiency is irrelevant. The reference most ventilation engineers use for this work is the ACGIH manual Industrial Ventilation: A Manual of Recommended Practice for Design.
Hoods and enclosures
A hood works by creating enough air velocity at the point where the contaminant is released to carry it into the hood. That velocity falls off quickly with distance from the hood face, so a hood placed a little too far away can lose most of its effect. The practical rules:
- Enclose as much as the process allows. A full or partial enclosure needs far less airflow than an open hood to achieve the same capture.
- Place the hood close to the source, and use the natural direction of the contaminant: hot fumes rise, grinding dust is thrown in the direction of rotation.
- Keep cross-draughts away. Fans, open doors and passing forklifts can blow fume past an open hood.
- Do not make operators fight the hood. If a hood blocks access, it will be moved or removed.
Ducts
Ducts must carry the contaminant without letting it settle, condense or attack the duct. Dust systems need a minimum transport velocity, which depends on the dust, so that particles stay airborne; below it, dust drops out in horizontal runs and gradually blocks the duct. Fume and vapour systems can run slower, but need corrosion-resistant materials and drainage where condensate forms. Balance the branches at design stage, with dampers or by sizing, so each hood receives its design airflow.
Fans and stacks
The fan is selected on the system curve: the airflow needed at the total pressure drop of hoods, ducts, treatment unit and stack. A treatment unit whose pressure drop rises in service, such as a filter loading with dust, moves the operating point, so the fan needs margin and preferably a variable-speed drive with pressure or airflow control.
The stack should discharge clean air where it disperses and cannot be drawn back into building air intakes, including the plant’s own fresh air intakes and those of neighbours. Sampling ports at the right location on the stack make performance testing possible later.
VOC control: capture, concentrate or destroy
Where VOCs come from
VOCs are carbon-based compounds that evaporate readily at room temperature. In industry they come mostly from solvents: in paints and coatings, printing inks, adhesives, cleaning agents and chemical processes. Spray booths, drying ovens, printing presses and mixing rooms are the usual sources. Besides health and odour effects, many VOCs are flammable, which shapes the design of every system that handles them.
TVOC (total volatile organic compounds) is a summary measure of the combined concentration. It is useful for trends and monitoring, but treatment design needs the individual compounds, because they behave differently in each technology.
Capture at source first
The cheapest VOC treatment is the airflow you do not have to treat. Enclose the source where possible, design booth and hood airflows to capture vapour at the point of release, and avoid diluting a small, concentrated stream with large volumes of general room air. Every m³/h you extract has to be moved by a fan and treated. Booth and hood design is part of the treatment system, not a separate trade.
Activated carbon adsorption
Activated carbon has a very large internal surface area that adsorbs VOC molecules from the air passing through it. Systems range from carbon filter panels in recirculating units to large adsorption towers packed with granular or pelletised carbon.
Carbon suits low airflows and low concentrations, intermittent processes and odour control. Its limitations:
- Carbon has a finite capacity. Once saturated, it must be replaced or regenerated, and the spent carbon is a waste stream to manage.
- Humid air reduces capacity, because water vapour competes for adsorption sites. In a tropical climate that matters, and pre-conditioning of the air is sometimes needed.
- Some compounds, notably certain ketones, can generate heat in carbon beds and cause hot spots. Systems for those solvents need temperature monitoring and appropriate safety measures.
- High concentrations consume carbon quickly, which makes running cost rise steeply.
Zeolite rotor concentrators
A zeolite rotor concentrator solves a common problem: a large airflow carrying a low VOC concentration, such as a spray booth exhaust. Treating that whole airflow in an oxidiser would need a very large unit and a lot of fuel to heat air that is mostly clean.
The rotor is a slowly turning honeycomb wheel coated with hydrophobic zeolite. The exhaust passes through most of the wheel, and VOCs are adsorbed. A small sector of the wheel is swept by a much smaller, heated desorption airflow, which releases the VOCs in concentrated form. That small, concentrated stream goes to an oxidiser (a regenerative thermal oxidiser or a catalytic oxidiser), where the VOCs are destroyed. Clean air from the main stream is discharged.
A complete zeolite system includes the rotor, process and desorption fans, heaters, dampers and a PLC with an operator panel. Zeolite is non-combustible and less affected by humidity than activated carbon, which suits warm, humid climates.
Regenerative thermal oxidisers (RTO)
An RTO destroys VOCs by oxidising them at high temperature into carbon dioxide and water vapour. Its defining feature is heat recovery: the exhaust passes through beds of ceramic media, which absorb heat from the hot, cleaned gas leaving the combustion chamber and give it back to the incoming gas. Valves switch the flow direction between beds at intervals.
Because most of the heat is recovered, an RTO can run on little or no auxiliary fuel when the VOC concentration is high enough for the solvent to supply the heat. The US EPA’s fact sheet on regenerative incinerators notes that destruction efficiency depends on chamber temperature, residence time, inlet concentration, the compounds involved and mixing. Those are the design variables to specify and verify.
RTOs suit continuous processes with moderate to high VOC concentrations, or the concentrated stream from a zeolite rotor. Catalytic oxidisers do the same job at lower temperatures with a catalyst, but catalysts can be poisoned by some compounds, such as silicones and certain metals, so the exhaust composition must be checked first.
Selection logic
| Exhaust condition | Usual first choice | Why |
|---|---|---|
| Low flow, low concentration, intermittent | Activated carbon | Simple, low capital cost |
| High flow, low concentration | Zeolite rotor plus oxidiser | Concentrates the VOCs, so the oxidiser stays small |
| Moderate to high concentration, continuous | RTO | Heat recovery makes destruction efficient |
| Mixed, variable or uncertain | Measure first, then decide | Wrong assumptions are expensive |
Equipment removal and destruction efficiencies are stated per project, on the manufacturer’s datasheet, for the measured exhaust conditions. Verify them by measurement at commissioning. Our article VOC control compared: activated carbon vs zeolite rotor vs RTO works through examples, and the air quality and emissions category shows the AirMax range, which we supply as technology partner and authorised distributor.
Dust collection: cartridge, baghouse or cyclone
Dust affects workers’ lungs, product quality, equipment wear and, for combustible dusts, plant safety. A dust collector system has four parts: capture hoods, ductwork, the collector, and a fan, and all four must be designed together.
Cartridge collectors
Cartridge collectors use pleated filter cartridges that pack a large filter area into a compact housing. Dust collects on the outside of the media and is removed periodically by pulses of compressed air, falling into a hopper.
They suit fine, dry dust at moderate loadings: grinding, cutting, welding fume, powder handling and cement transfer points. Their compact size suits plants short of space. Limits: sticky, oily, fibrous or very heavy dust loads tend to blind or bridge pleated media.
Baghouses
A baghouse (bag filter) uses long fabric bags, usually cleaned by pulse jet. Bags handle higher dust loadings, larger airflows, fibrous and abrasive dusts, and with the right fabric, higher temperatures. They are the usual choice for rice mills, feed mills, flour handling and many cement processes.
The key sizing parameter is the air-to-cloth ratio: airflow divided by filter area. Too high, and the pressure drop rises and dust is driven into the fabric. The right figure depends on the dust, the fabric and the cleaning system, and comes from the manufacturer’s design data.
Cyclones
A cyclone separator spins the dusty air so that centrifugal force throws particles to the wall, where they fall into a hopper. Cyclones have no filter media, handle high temperatures and heavy loads, and are cheap to run. But they are efficient mainly for coarse particles, and much less so for fine dust. They are used for wood chips, rice husk and other coarse material, and as pre-separators in front of a bag or cartridge filter to reduce its load.
| Collector | Dust it handles best | Strengths | Watch out for |
|---|---|---|---|
| Cartridge | Fine, dry, moderate loading | Compact, high filter area | Sticky or fibrous dust |
| Baghouse | Heavy, fibrous, abrasive, hot | Large airflows, heavy loads | Footprint, fabric selection |
| Cyclone | Coarse particles, heavy loads | No media, low maintenance | Poor on fine dust |
Our article dust collection for cement, rice and feed mills covers these industries in detail. See also cement and building materials and agro-processing.
Humid dust in a humid climate
Many dusts are hygroscopic. Cement, fertiliser, sugar and some feed ingredients absorb moisture and turn sticky, which blinds filter media and bridges in hoppers. In a tropical climate this is common. Design responses include selecting media and coatings suited to the dust, keeping the collector and hopper above the dew point of the gas, and making sure the compressed air used for pulse cleaning is dry. The compressed air guide covers drying that air.
Odour: contain, extract, then treat
Odour is a mixture, often of many compounds at very low concentrations. It is also subjective, which makes it a frequent source of complaints from neighbours. The European standard EN 13725 defines how odour concentration is measured by dynamic olfactometry, in European odour units, using a panel of trained assessors. It gives you a number to design and verify against.
Containment and extraction come first: covering tanks, enclosing conveyors and keeping odorous areas under slight negative pressure so odour does not escape. Treatment then follows the compounds and the load:
- Activated carbon for low and intermittent loads. Impregnated carbons target specific compounds such as hydrogen sulphide.
- Biofilters, where microorganisms on a moist media bed break down biodegradable odorous compounds. They suit steady loads from food processing, composting and wastewater treatment, but need stable moisture and temperature in the bed.
- Chemical scrubbers, which absorb and neutralise compounds in a recirculating liquid: an alkaline or oxidising solution for hydrogen sulphide, an acidic solution for ammonia and amines.
Many odour systems combine stages, for example a chemical scrubber for the bulk load followed by carbon for polishing. See water and wastewater and food and beverage.
Acid fumes and soluble gases: wet scrubbers
Plating, pickling, etching, chemical production and laboratories release acid and alkaline fumes. These gases are corrosive to people, buildings and equipment. They are usually soluble in water or in a reagent solution, which is why wet scrubbers are the standard answer.
Packed bed scrubbers
A packed bed scrubber passes the gas up through a bed of plastic packing while a scrubbing liquid flows down over it. The packing creates a large wetted surface, so the gas and liquid have long contact. Soluble gases such as hydrogen chloride and ammonia are absorbed and neutralised: an alkaline solution such as caustic soda for acid gases, an acidic solution for ammonia.
The liquid recirculates from a sump with pH control and chemical dosing, and a bleed of spent liquid goes to wastewater treatment. A mist eliminator at the top stops droplets leaving the stack. With suitable mist elimination, packed beds are also used on acid mists from tanks such as sulphuric acid baths.
Venturi scrubbers
A venturi scrubber accelerates the gas through a narrow throat where scrubbing liquid is injected. The high velocity shatters the liquid into fine droplets that capture fine particles, mists and fumes. Venturis are effective on fine particulate and sticky or wet dust that would blind a dry filter. The trade-off is pressure drop: the higher the collection efficiency required, the higher the fan energy.
Wet scrubbers in general
The term wet scrubber covers spray towers and other designs that bring gas and liquid into contact. They are used for odours, chemical gases and mixed duties. The design questions are the same for all:
- Chemistry: which compounds, which reagent, what pH or redox control.
- Materials: polypropylene, PVC or fibre-reinforced plastic resist most acids and alkalis. Carbon steel usually does not.
- Water and effluent: make-up water supply and the treatment of the bleed stream.
- Fan and duct: corrosion-resistant fans and ductwork, and duct slopes to drain condensate.
| Scrubber | Best for | Key design variable |
|---|---|---|
| Packed bed | Soluble acid and alkaline gases | Contact surface, liquid rate, pH control |
| Venturi | Fine particles, mists, sticky dust | Throat velocity and pressure drop |
| Spray tower and other wet scrubbers | Odours, mixed chemical gases | Droplet contact and reagent chemistry |
See chemicals and printing and coating for industry context.
Clean rooms and positive pressure
A clean room controls the concentration of airborne particles, and often temperature, humidity and pressure, to protect a product or a process. Pharmaceutical manufacturing, hospitals, laboratories and electronics assembly use them.
ISO 14644-1 classes explained
ISO 14644 is the international series for clean rooms. Part 1, ISO 14644-1:2015, classifies air cleanliness by the maximum number of particles per m³ at or above specified sizes. Each class number is ten times cleaner than the next at a given particle size. The limits follow the formula Cn = 10^N × (0.1/D)^2.08, where N is the class number and D the particle size in µm. The table summarises the published limits.
| ISO class | ≥ 0.1 µm | ≥ 0.5 µm | ≥ 1 µm | ≥ 5 µm |
|---|---|---|---|---|
| 4 | 10,000 | 352 | 83 | not classified |
| 5 | 100,000 | 3,520 | 832 | not classified |
| 6 | 1,000,000 | 35,200 | 8,320 | 293 |
| 7 | not applicable | 352,000 | 83,200 | 2,930 |
| 8 | not applicable | 3,520,000 | 832,000 | 29,300 |
| 9 | not applicable | 35,200,000 | 8,320,000 | 293,000 |
Pharmaceutical clean rooms in many markets follow GMP guidance as well. EU GMP Annex 1, revised in 2022, defines grades A to D for sterile manufacturing, with particle limits linked to ISO 14644-1 classes, and adds requirements for microbial monitoring, airflow visualisation and pressure differentials. The right class or grade comes from your product, your process and the regulatory guidance that applies to it.
HEPA filters: H13 and H14
The final filters in a clean room are HEPA filters. In Europe they are classified by EN 1822-1, which tests filters at the most penetrating particle size (MPPS), the size at which the filter medium is least efficient.
| EN 1822-1 class | Integral efficiency at MPPS | Local efficiency at MPPS |
|---|---|---|
| H13 | ≥ 99.95% | ≥ 99.75% |
| H14 | ≥ 99.995% | ≥ 99.975% |
H14 lets through a tenth of the particles that H13 does at the MPPS. EN 1822 also defines lower E classes and higher U (ULPA) classes, and ISO 29463 is the international counterpart. Once installed, filters must be leak-tested in place, because a perfect filter in a leaking frame gives a leaking room. ISO 14644-3 describes the installed filter leakage test.
Positive pressure, airlocks and pass boxes
A clean room is kept at a higher pressure than its surroundings, so air flows out through gaps and doorways and unfiltered air cannot leak in. In a suite of rooms, the pressure steps down from the cleanest room to the least clean, which is called a pressure cascade. EU GMP Annex 1 gives a guidance value of at least 10 Pa between adjacent rooms of different grades.
The supporting elements:
- Airlocks between zones, with interlocked doors so both cannot open at once.
- Pass boxes for moving materials in and out without opening the room door. Dynamic pass boxes have their own HEPA-filtered airflow.
- Laminar flow units, which supply unidirectional HEPA-filtered air over a critical work zone, such as filling or aseptic handling.
- Differential pressure gauges or sensors at each door, with alarms.
Positive pressure is not always the answer. Rooms handling potent compounds, infectious material or hazardous chemicals may need to be at lower pressure than their surroundings, to protect people outside. In those cases, airlocks and cascades are designed to contain the hazard while still protecting the product.
The air system behind a clean room is an AHU with staged filtration, cooling, often dehumidification, and terminal HEPA filters. The Nexus range of HVAC and chillers supplies the cooling and air handling. Capacities selected to your load. Ask for a datasheet. Our dehumidification guide covers humidity control for these spaces, and clean rooms and positive pressure: basics for pharma, hospitals and labs goes further. See also pharmaceutical and healthcare and electronics.
A perfect filter in a leaking frame gives you a leaking room.
Filtration classes: from EN 779 to ISO 16890
General ventilation filters, the pre-filters and secondary filters in air-handling units, used to be classified under EN 779. The 2012 edition grouped them as coarse filters G1 to G4, medium filters M5 and M6, and fine filters F7 to F9, based on average efficiency against 0.4 µm particles.
EN 779:2012 has been withdrawn and replaced by ISO 16890, published in 2016. Filter manufacturers describe an 18-month transition period, with EN 779 withdrawn in mid-2018. ISO 16890 rates filters against three fractions of particulate matter that match how air quality is reported outdoors: PM1, PM2.5 and PM10.
| ISO 16890 group | Requirement | What it tells you |
|---|---|---|
| ISO ePM1 | At least 50% efficiency against PM1 | Captures the finest particles, including combustion particles |
| ISO ePM2.5 | At least 50% efficiency against PM2.5 | Captures fine particles |
| ISO ePM10 | At least 50% efficiency against PM10 | Captures coarser respirable particles |
| ISO Coarse | Below 50% against PM10 | Rated by arrestance; pre-filters |
A filter is reported with its group and its efficiency, rounded down in 5% steps, for example “ISO ePM1 70%”. The test also measures efficiency after the filter media has been electrostatically discharged, so a filter cannot earn its class from an electrostatic charge that fades in service.
HEPA filters are outside the scope of ISO 16890. They are classified under EN 1822 or ISO 29463, as described above. Our article air filter classes explained: EN 779, ISO 16890, panel, pocket and HEPA covers filter formats, and the filters and media category lists pre-filters, panel, pocket and activated carbon filters, paint-stop media and high-temperature panels.
Every filter adds pressure drop, and pressure drop is fan energy. Choose filters for the efficiency you need and replace them on measured differential pressure, not by calendar alone.
Monitoring: measure what you are controlling
An air quality system without measurement is a hope. Monitoring tells you whether the system works today, warns you before it stops working, and gives you records for auditors, customers and regulators.
| Parameter | What it indicates | Notes |
|---|---|---|
| PM2.5 and PM10 | Fine and coarse particle levels | The WHO 2021 Air Quality Guidelines set ambient 24-hour levels of 15 µg/m³ (PM2.5) and 45 µg/m³ (PM10) |
| CO₂ | Ventilation adequacy in occupied spaces | An indicator of fresh air, not of pollution from the process |
| TVOC | Combined volatile organic compounds | Sensors give a relative signal; compound-specific monitoring needs other methods |
| Temperature and humidity | Comfort, product and process conditions | Also affects filter and adsorbent performance |
| Differential pressure | Filter loading and room pressure cascades | The most useful single measurement in clean rooms |
| Air velocity | Hood capture and laminar flow | Checks that capture airflow is maintained |
A few practical points:
- Sensor grade matters. Low-cost optical particle sensors and metal-oxide TVOC sensors are good for trends, comparisons and alarms. Compliance measurements, such as stack testing or occupational exposure assessments, need reference methods and qualified laboratories.
- Location matters. Put sensors where people breathe, where product is exposed and where the risk is highest, not only where cabling is convenient.
- CO₂ is a ventilation proxy. Outdoor air today contains a little over 400 ppm. Indoor levels well above that show how much exhaled air is building up relative to the fresh air supplied.
- Workplace limits are separate. Occupational exposure limits for specific chemicals and dusts are set by national regulators and bodies such as ACGIH. The WHO guidelines above are for ambient air, not workplaces.
Nexus AirSight brings PM2.5, PM10, CO₂, TVOC, temperature, humidity, pressure, air velocity, differential pressure and filter status onto one screen through a SCADA layer, with real-time values, trends, alarms and reports, alongside the plant’s other utilities.
Scoping an air quality project
A good air quality project starts with data, not a catalogue. These are the questions we work through with you before recommending equipment.
What we need to scope an air quality or emissions project
- What is the contaminant: compounds, dust type, odour source or clean room class?
- Where is it generated, and can it be enclosed or captured closer to the source?
- Airflow at each capture point, measured or estimated from hood design
- Concentration, from measurement or the material balance of solvents used
- Exhaust temperature and humidity
- Operating hours and how the load varies across a shift
- Permit limits, customer codes of conduct and workplace exposure limits that apply
- Fire and explosion hazards: flammable solvents, combustible dust
- Waste streams: spent carbon, collected dust, scrubber bleed, and how they will be handled
- Space, structural support, power, water and fuel available
- Monitoring and records required
From there, the project follows the same stages as any utility we deliver: survey and measurement, capture and duct design, technology selection, detailed design and engineering, supply, installation and commissioning with measured performance, and a maintenance contract with spare parts for filters, media and consumables.
Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage. For emissions control, the baseline is usually measured concentration and flow before and after, plus the energy and consumables the system uses to achieve it.
Where to go next
- Equipment: air quality and emissions, filters and media, HVAC and chillers, and the AirMax brand page.
- Solutions: air quality and emissions, HVAC and cooling, SCADA and monitoring, humidity control.
- Articles: VOC control compared, dust collection for cement, rice and feed mills, air filter classes explained, clean rooms and positive pressure.
- Industries: plastics and packaging, printing and coating, chemicals, cement and building materials.
- Tools: the system selector recommends a direction from a few questions, and the unit converter handles flow and pressure units.
- Related guides: compressed air and industrial dehumidification.
If you have an exhaust to treat, a dust problem or a clean room to build, send us what you know. Request a quote or contact the engineering team.