Treat the compounds that cause the smell
Odour complaints can bring a plant under pressure from neighbours and authorities. The smell itself usually comes from a small number of compounds, often sulphur compounds such as hydrogen sulphide, nitrogen compounds such as ammonia and amines, or organic compounds from food and chemical processes. The right treatment depends on which ones are present. AirMax supplies three approaches:
- Activated carbon, which adsorbs a broad range of odorous compounds and suits low to moderate loads.
- Bio-filters, in which microorganisms living on a moist media bed break odorous compounds down. They suit continuous, biodegradable odours.
- Chemical scrubbers, which absorb odorous gases into a reactive liquid. They suit higher concentrations of compounds such as ammonia and hydrogen sulphide.
Capacities are selected to your load. Ask for a datasheet.
How it works
Odorous air is captured at source by covers, hoods and extraction, then ducted to the treatment unit. In a carbon unit it passes through carbon beds. In a bio-filter it passes slowly through a moist bed of media where microorganisms consume the compounds. In a wet scrubber it contacts a recirculated liquid chosen for the chemistry. Many systems combine stages, such as a scrubber for the bulk load followed by carbon polishing.
Where it fits
- Wastewater treatment plants, sludge handling and pumping stations.
- Food processing, rendering and fish processing.
- Waste handling and composting.
- Chemical and fermentation processes.
Selection notes
- Identify the compounds. Process knowledge and, where needed, sampling tell us which compounds dominate.
- Contain first. Covering tanks and enclosing processes reduces the airflow to treat and makes treatment more effective.
- Climate suits bio-filters, with care. Warm temperatures support biological activity, but beds must stay evenly moist and not waterlogged in the monsoon.
- Humidity and carbon. Humid air reduces carbon capacity for some compounds, which affects carbon life.
- Neighbours. Stack height and discharge position matter as much as treatment efficiency for complaint risk.
What Nexus provides
Odour source survey, containment and extraction design, technology selection, installation and commissioning, and planned maintenance including media replacement, bio-filter care and scrubber dosing checks.