Phnom Penh, serving Cambodia and the region

Compressed air

Compressed Air Leaks: Finding and Fixing a Hidden Cost

Why compressed air leaks cost more than they look, how to measure your leak rate, and how to run a find, tag, fix and verify programme that keeps leaks down.

Nexus Turnkey Engineering Team6 min read

Leaks run every hour your compressors do

Compressed air leaks cost money every hour your compressors run, whether the line is producing or not. They are easy to ignore because they make little noise on a busy floor and appear on no invoice. The US Department of Energy’s compressed air sourcebook, written with the Compressed Air Challenge, states that poorly maintained systems can lose 20 to 30 percent of their air capacity and power to leaks, and that a well-maintained system should be below 5 to 10 percent. The fix is a programme, not a one-off: measure the leak rate, find leaks with ultrasonic leak detection, tag them, repair them, then measure again.

This article explains why leaks cost more than they look and how to run a programme that keeps them down. It sits within our industrial compressed air guide.

Why leaks cost more than they look

They never clock off

A leak consumes air whenever the system is pressurised. If compressors run through breaks, nights and weekends to keep a few machines ready, every leak runs too. Off-production demand is often mostly leakage, which is why it is one of the first things a compressed air audit measures.

Small holes grow fast

Flow through a small opening rises with its area, which means with the square of its diameter. Double the diameter of a hole and, at the same pressure, roughly four times as much air escapes. A worn hose connection that starts as a hiss can become a significant flow without anyone noticing a change.

Pressure feeds them

At typical plant pressures, flow through a leak rises roughly in proportion to absolute pressure. So a plant running a higher header pressure than it needs loses more air through every leak, on top of the extra energy needed to compress every cubic metre. The DOE sourcebook notes that raising discharge pressure increases the consumption of every unregulated use, leaks included. Our pressure reduction savings tool shows how setpoint and leakage interact.

They hide other costs

The same DOE guidance notes that leaks also lower system pressure, make tools and machines perform worse, lengthen compressor running hours, add maintenance, and can lead a plant to buy compressor capacity it does not need.

A leak runs three shifts a day, seven days a week, whether or not the line is running.

Measure the leak rate first

Before you hunt for individual leaks, find out how big the problem is. Measure your leak rate with production stopped and all air-using machines idle, but the system pressurised.

Load and unload timing. For a compressor with load/unload control, the DOE sourcebook gives a simple method. Record the average time the compressor runs loaded (T) and unloaded (t) over several cycles, while only leaks are consuming air. Then:

Leakage (%) = (T × 100) ÷ (T + t)

The result is the share of that compressor’s capacity lost to leaks. For example, if it runs loaded for 2 minutes and unloaded for 6, leakage is 2 × 100 ÷ 8 = 25 percent of its capacity.

Pressure decay. For variable-speed compressors or other controls, the same source describes timing how long the system takes to fall from operating pressure to about half that pressure, with the compressors stopped. With an estimate of the total system volume, including receivers and piping, this gives a leakage flow.

Both methods have limits. They can miss air consumed by idle machines that were not fully isolated. But they give a baseline, and a baseline is what lets you prove the programme worked.

Once you have a leak flow, our leak cost calculator turns it into an annual cost using your electricity price and running hours.

Find, tag, fix, verify

A leak programme has four steps. Each one produces a record.

StepWhat to doOutput
FindSurvey the whole system with an ultrasonic detector, during production if neededEach leak located and sized
TagAttach a numbered tag at each leak and log itLeak register: location, estimated size, priority
FixRepair in priority order; larger leaks and easy fixes firstRegister updated with date and repair method
VerifyRepeat the leak-rate test under the same conditionsMeasured leak rate before and after

Ultrasonic detection works because escaping air produces high-frequency sound, most of it above human hearing. The detector converts that sound into an audible signal and a reading, so the surveyor can locate leaks on a working floor. The DOE sourcebook describes it as probably the most versatile leak-detection method.

Where leaks hide

The DOE sourcebook lists the most common problem areas. On a plant floor, that means checking:

  • threaded joints and pipe connections, especially where sealant has aged;
  • hose connections and drops to machines, where hoses are moved and flexed;
  • condensate drains stuck open, or timer drains set to open too often;
  • flanges and unions on older, corroded sections of the main;
  • machine-side connections inside guards, where nobody looks;
  • disused branches that were never isolated or capped.

Make it a programme, not an event

Leaks come back. Joints age, hoses wear, machines are moved and new lines are added. A plant that surveys once, repairs everything and then stops will see the leak rate climb again.

What works is a routine:

A leak programme that lasts

  • Measure the leak rate and record it as a baseline
  • Survey the full system with an ultrasonic detector
  • Tag and log every leak with location, size and priority
  • Repair in priority order and record each repair
  • Re-measure the leak rate under the same conditions
  • Isolate or remove disused branches
  • Lower the header pressure to the lowest level that works
  • Repeat the survey at an interval set by how fast leakage returns

Give the programme an owner. Leak work slips when it belongs to everyone. Name one person to hold the leak register, schedule surveys and report the leak rate to management. Build repairs into planned maintenance, so parts and labour are ready, and make leak checks part of every machine move or line change. A maintenance contract can carry the survey and re-measurement as scheduled tasks.

Track one number over time: leak flow as a share of total demand, measured the same way each time. If it rises, survey again sooner. If it holds, the interval can stretch.

What fixing leaks is worth

The value depends on your leak rate, electricity price, running hours and how well your compressors reduce power as demand falls. A fixed-speed compressor running more hours unloaded after repairs may save less than expected, which is why control and leak repair are often planned together. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.

Start with the baseline

If you have never measured your leak rate, start there. It takes a non-production window, a watch and a notebook. If the number is high, a structured survey is the next step.

Our compressed air leak detection service covers survey, tagging, a priority register and re-measurement. It fits naturally inside a wider energy optimisation programme. For what an audit covers beyond leaks, read what a compressed air audit is. Then ask an engineer to measure what your leaks cost.

Nexus Turnkey Engineering Team

Written and reviewed by the engineers who design, install and maintain industrial air systems for Nexus Turnkey in Cambodia. Questions about this article? Ask us directly.

FAQ

Questions engineers ask us

How much of our compressed air is likely to be leaking?

You need to measure it. For reference, the US DOE compressed air sourcebook states that poorly maintained systems can lose 20 to 30 percent of air capacity and power to leaks, and that a well-maintained system should be below 5 to 10 percent. A simple load and unload timing test with production stopped gives a first figure for your plant.

Can we find leaks by listening during a quiet period?

Large leaks, yes. Most leaks are too small or too high-pitched to hear, and a plant is rarely quiet enough. An ultrasonic leak detector picks up the high-frequency sound of escaping air and works during production, which is why it is the standard survey tool.

How often should we survey for leaks?

New leaks appear as joints age, hoses wear and machines are moved. A one-off survey gives a one-off result. Most plants benefit from a repeated programme, with the interval set by how quickly the measured leak rate climbs back after each round of repairs.

Does lowering system pressure reduce leakage?

Yes. Air flows through a leak faster at higher pressure, so a lower header pressure reduces leak flow as well as the energy needed to compress every cubic metre. The DOE sourcebook makes this point. Repairs are still the main fix, because lower pressure only reduces leaks, it does not remove them.

Next step

Turn this into a plan for your plant.

Send us your situation and an engineer will reply with the questions that matter and a sensible next step.

Start typing to search