A ring main is a distribution header that forms a closed loop around the production area. Air can flow to any drop from both sides, so the velocity in each leg, and the pressure drop, is lower than in a single dead-end line of the same size.
Dead-end mains that grew with the factory are a common cause of low pressure at the far machines, which plants then “fix” by raising compressor pressure for everyone. A properly sized loop lets the whole hall run at a lower set point.
Practical note: good practice is to take drops from the top of the header so condensate stays in the main, lay the main with a slight fall towards drain points, fit isolation valves so sections can be worked on without shutting the plant, and size for planned expansion.