Phnom Penh, serving Cambodia and the region

Compressed air

Heat Recovery From Air Compressors: Turning Waste Heat Into Hot Water

Most of a compressor's electricity ends up as heat. How compressor heat recovery turns it into hot water for process, boiler feed and washing in hot climates.

Nexus Turnkey Engineering Team6 min read

Most of the power you buy comes back as heat

Compressor heat recovery captures the heat an air compressor must reject anyway and uses it to make hot water or warm air. The scale is large. The Compressed Air Challenge, in its fact sheet on heat recovery, states that as much as 80 to 93 percent of the electrical energy used by an industrial air compressor is converted into heat. With a properly designed system, it says 50 to 90 percent of that thermal energy can often be captured and reused.

In Cambodia nobody needs space heating, so the value lies in hot water: boiler feedwater, process washing, dyeing, cleaning and canteen use. If your plant heats water with diesel, LPG, biomass or electricity, a compressor next door may already be producing a share of that heat for nothing. This article explains how it works and how to tell whether it fits. It is part of our industrial compressed air guide.

Where the heat comes from

Compressing air raises its temperature. In an oil-injected screw compressor, the oil absorbs most of that heat and carries it to an oil cooler. The rest leaves through the aftercooler, which cools the compressed air before treatment, and through the motor and its cooling.

That gives two practical recovery points:

  1. The oil circuit. A plate heat exchanger in the hot oil line transfers heat to water. This is where most recoverable energy sits, and it is the usual choice for hot water.
  2. The cooling air. On air-cooled packages, the hot air leaving the cabinet can be ducted to where warm air is useful, such as a drying process. In a tropical plant that hot air is usually more of a nuisance than an asset, and it must be ducted out of the room. Our article on compressor room design for tropical heat covers that side.

Water-cooled compressors can also feed a recovery circuit, though the Compressed Air Challenge notes the available temperature is lower and typical recovery efficiencies are more modest, around 50 to 60 percent. Oil-free compressors have their own heat paths through intercoolers and aftercoolers; the recovery arrangement depends on the model.

On a variable speed compressor, heat output follows air demand. When the plant needs less air, the motor slows and less heat is available. That is not a reason to avoid recovery, but it is a reason to base the design on the compressor’s measured load profile rather than its full-load rating.

How a hot water recovery system is built

A typical package for an oil-injected rotary screw compressor includes:

  • A plate heat exchanger in the oil circuit, sized to the compressor’s heat output.
  • A thermostatic valve that sends oil through the recovery exchanger first and through the standard oil cooler when the water side cannot absorb the heat.
  • A water circuit with a pump, an insulated storage tank and controls.
  • Temperature and flow instruments so recovered energy can be measured.

Water quality matters too. The Compressed Air Challenge notes that heat exchangers can produce potable or non-potable water depending on design. For anything a person might drink or wash food with, use an exchanger designed for potable duty.

Matching heat supply to heat demand

The heat supply follows the compressor’s loading. A compressor running fully loaded through two shifts is a steady source. A trim machine that loads and unloads all day is not. The demand side has its own profile. Recovery works best where the two overlap, or where a storage tank bridges the gap.

Heat sinkFit for recovered heatWhat to check
Boiler feedwater preheatStrong where the boiler runs during compressor hoursFeedwater temperature and flow, water treatment
Process wash waterStrong in food, beverage and textile plantsDaily volume and timing
Dye house and laundry waterStrong in garment and textile plantsRequired temperature, peak draw
Canteen and washroom hot waterModest but steadyPotable-grade exchanger
Warm air for dryingPossible, process-specificDucting, dust, air quality

Garment and textile plants are good candidates because dyeing and washing use large volumes of warm water. See our garment and textile industry page. Food and beverage plants are another, with washdown and cleaning-in-place duties.

Heat recovery pays where a steady compressor meets a steady hot water demand. Everything else is detail.

How to estimate the opportunity

A first estimate needs only a few numbers, all of which can be measured:

  1. Compressor electrical input in kW, and its loaded hours per year. Metering is better than nameplate.
  2. Recoverable fraction. Use the recovery equipment supplier’s figure for your model and operating point. Treat public ranges, such as those above, as a sense check only.
  3. Recovered heat per year in kWh: input kW × loaded hours × recoverable fraction, limited to what your hot water demand can absorb.
  4. Fuel displaced. Divide recovered kWh by the efficiency of the heater it replaces, then by the energy content of that fuel.
  5. Cost of the recovery system, including piping, pump, tank, controls and installation.

The Compressed Air Challenge stresses comparing recovered heat with the actual current source of thermal energy, because a cheap fuel makes the case weaker. Our compressed air cost calculator helps establish the electrical side first.

When it comes to results, savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.

Mistakes that weaken a heat recovery project

  • Sizing on nameplate power. A compressor that runs part loaded or unloaded for long periods produces far less heat than its motor rating suggests. Use metered data.
  • Recovering from the trim machine. In a multi-compressor hall, the base-load machine is the steady heat source. A trim or variable speed machine follows demand and gives a variable heat supply.
  • No storage. Without an insulated tank, heat produced when nobody needs hot water is simply rejected through the standard cooler.
  • Ignoring water quality. Hard water scales plate heat exchangers. Treat or soften the water side, and fit isolation valves so the exchanger can be cleaned.
  • No metering. Without a heat meter on the water side, nobody can say what the system delivers, and faults go unnoticed.

A short feasibility checklist

  • Metered kW and loaded hours for each compressor, ideally over a representative week
  • Compressor type, cooling method and model, to confirm the recovery arrangement
  • Every hot water use on site, with volume, temperature and timing
  • The current heater, its fuel and an honest estimate of its efficiency
  • Distance and route from the compressor room to the hot water user
  • Space for a heat exchanger, pump and storage tank
  • Whether any recovered water must be potable

A compressed air audit is a natural place to collect most of this, because it already measures load profiles and hours. Our energy optimisation solutions bring heat recovery together with leak control, pressure management and sequencing.

Put the heat to work

If your compressors run steady hours and your plant heats water, heat recovery deserves a proper look. We measure the compressor load, map the hot water demand and design a recovery circuit that protects the compressor first. Recovery packages can be specified with new Ingersoll Rand and Sollant machines from our air compressors range or retrofitted to many existing ones. Ask us which arrangement fits your models.

Nexus Turnkey Engineering Team

Written and reviewed by the engineers who design, install and maintain industrial air systems for Nexus Turnkey in Cambodia. Questions about this article? Ask us directly.

FAQ

Questions engineers ask us

How much heat can I recover from an air compressor?

The Compressed Air Challenge fact sheet on heat recovery states that as much as 80 to 93 percent of the electrical energy used by an industrial compressor becomes heat, and that a properly designed system can often capture 50 to 90 percent of that heat. What you actually recover depends on the compressor type, its loading and how steadily you use the hot water.

Is heat recovery worth it in a hot country with no space heating?

It can be, if the plant uses hot water. Boiler feedwater, process washing, dyeing, cleaning and canteen hot water are all common sinks. Without a steady hot water demand, the heat has nowhere useful to go.

Will heat recovery affect compressor cooling?

It must not. A correct design keeps the compressor's own cooler in the circuit, with a thermostatic valve that routes heat to the standard cooler whenever the hot water side cannot take it. Compressor protection always comes first.

Can recovered heat make drinking-quality hot water?

Only with a heat exchanger designed for potable water, typically with a protective barrier between the compressor oil and the water. Otherwise the recovered water should be treated as non-potable process water.

Next step

Turn this into a plan for your plant.

Send us your situation and an engineer will reply with the questions that matter and a sensible next step.

Start typing to search