Refrigerated vs Desiccant Dryers and ISO 8573-1 Classes, Explained

Refrigerated or desiccant dryer? How pressure dew point and ISO 8573-1 water classes decide, what each dryer costs to run, and how to size one for tropical air.

Nexus Turnkey Engineering Team6 min read

Choose the dryer by the dew point you need

A refrigerated dryer cools compressed air so water condenses and drains away. It typically reaches a pressure dew point of around +3 °C, which is ISO 8573-1:2010 water Class 4, and it suits most general plant air. A desiccant dryer adsorbs water onto a desiccant bed and reaches -40 °C (Class 2) or even -70 °C (Class 1). You need it when the air or the piping can get colder than +3 °C, or when the process demands very dry air. Choose by the class each user needs, then size the dryer for real tropical inlet conditions, not datasheet ones.

This article explains pressure dew point, the ISO 8573-1 classes, how the two dryer families compare, and how to specify one. It is part of our industrial compressed air guide.

Pressure dew point, in plain terms

Air holds water vapour. Cool it far enough and the vapour condenses. The temperature at which that starts is the dew point. Compressing air squeezes the same water into a smaller volume, so condensation begins at a higher temperature. The dew point of compressed air, measured at its working pressure, is the pressure dew point.

The rule that matters is simple. Liquid water forms anywhere the compressed air, or the pipe carrying it, is colder than its pressure dew point. Keep every part of the system warmer than the pressure dew point and the air stays dry.

This is why tropical plants carry a large drying load. Standard psychrometric tables put saturated air at 30 °C at about 30 g of water vapour per m³, roughly three times the figure at 10 °C. A compressor in a hot, humid plant takes in a lot of water, and most of it has to be removed by the aftercooler, separators, drains and dryer.

The ISO 8573-1 classes you will meet

ISO 8573-1:2010 expresses compressed air purity as three class numbers: particles, water and oil. For drying, the water class matters. For oil-injected compressors, the oil class decides the filtration.

ClassWater: pressure dew pointTotal oil (aerosol, liquid, vapour)
0As specified by the user, stricter than Class 1As specified by the user, stricter than Class 1
1≤ -70 °C≤ 0.01 mg/m³
2≤ -40 °C≤ 0.1 mg/m³
3≤ -20 °C≤ 1 mg/m³
4≤ +3 °C≤ 5 mg/m³
5≤ +7 °C—
6≤ +10 °C—

Refrigerated and desiccant dryers compared

The figures in this table come from the US Department of Energy’s compressed air sourcebook, written with the Compressed Air Challenge, unless stated otherwise.

RefrigeratedHeatless desiccantHeated or heat-of-compression desiccant
Typical pressure dew pointAbout +2 to +4 °CTypically rated at -40 °CTypically rated at -40 °C
How it removes waterCools air, drains condensateAdsorbs onto desiccant; dry air purges the off-line towerAdsorbs onto desiccant; heat regenerates it
Main running costRefrigeration power and pressure dropPurge air, 10 to 18 percent of rating for pressure-swing typesHeater or blower power, little or no purge; heat-of-compression types need hot air from oil-free compressors
FitsGeneral plant air in warm roomsSmall to medium flows needing low dew pointsLarger flows needing low dew points

The same source puts the typical pressure drop through a compressed air dryer at 3 to 5 psi, roughly 0.2 to 0.35 bar. That drop is paid for at the compressor, so it belongs in the comparison.

Liquid water forms wherever the air, or the pipe carrying it, is colder than its pressure dew point.

When the tropics change the answer

In a warm Cambodian plant, most pipework never gets close to +3 °C. A refrigerated dryer is often the right choice for general plant air. But check three situations carefully.

Cold spaces. Air lines that run through cold rooms, chilled stores or heavily air-conditioned areas can cool below a refrigerated dryer’s dew point. Condensation then forms inside the pipe at that point.

Sensitive processes. Some pharmaceutical, electronics and food applications specify drier air. The British Compressed Air Society’s food-grade guideline, for example, recommends ISO 8573-1:2010 Class 2.2.1 for air in direct contact with food, which means a -40 °C pressure dew point, and Class 2.4.2 for indirect contact.

Hot inlet air. Dryers are rated at reference inlet and ambient temperatures. The DOE sourcebook says dryers must be sized for the worst-case inlet temperature, system pressure and ambient temperature. In a hot compressor room, a dryer chosen on nominal flow alone can be undersized, and the dew point drifts up exactly when the air is wettest. Apply the manufacturer’s correction factors for your conditions.

Filtration and condensate go with the dryer

A dryer works as part of a treatment train, not on its own.

  • A coalescing filter upstream protects a desiccant bed from oil and liquid water.
  • A particulate filter downstream of a desiccant dryer catches desiccant dust, which the DOE sourcebook also recommends.
  • For oil-injected compressors, an activated carbon stage may be needed to reach a strict oil class.
  • Drains on the aftercooler, separator, receiver, dryer and filters must work. Zero-loss drains remove condensate without blowing off compressed air.
  • Oily condensate needs treatment before discharge. The DOE notes that discharging it untreated is no longer acceptable. An oil-water separator handles that.

Don’t over-dry

The DOE advises drying only to the degree needed, because unnecessarily low dew points cost energy and maintenance. If only one or two users need -40 °C air, a small point-of-use desiccant dryer after a central refrigerated dryer may cost less to run than drying the whole plant to -40 °C.

Keep the dryer doing its job

A dryer that worked at commissioning can drift. In hot, dusty plant rooms, a few checks keep it honest.

  • Measure dew point continuously. A dew-point sensor at the dryer outlet, with an alarm, shows a problem before wet air reaches users.
  • Keep condensers clean. An air-cooled refrigerated dryer rejects heat through a condenser. Dust on the fins raises the refrigerant temperature and the dew point with it.
  • Check drains. A blocked drain sends liquid water straight downstream, whatever the dryer is doing.
  • Watch pressure drop. Rising differential pressure across a dryer or filter means energy lost at the compressor, and often a saturated element.
  • Replace desiccant on condition. Oil and liquid water contaminate desiccant beds. Replace them when performance falls, not only when the calendar says so.

Specifying a compressed air dryer

  • List each user and the ISO 8573-1 class it needs
  • Find the coldest point any air line passes through
  • Use measured flow, not total compressor nameplate
  • Use worst-case inlet temperature, pressure and room ambient
  • Apply the manufacturer's correction factors for those conditions
  • Include filter and dryer pressure drop in the energy comparison
  • Plan drains and condensate treatment
  • Install a dew-point sensor so performance can be checked

Next steps

If you are not sure what dew point your air reaches today, measure it. A compressed air audit includes pressure dew point at key points, which often explains wet air, corrosion or filter problems. For the other half of the quality decision, read our article on oil-free vs oil-injected compressors.

We supply refrigerated and desiccant dryers, filters and drains as part of our air treatment range, and size them to your conditions. If your plant serves food or pharmaceutical production, see how we approach air for food and beverage plants. Send us the ISO class you need and your flow, and an engineer will propose a treatment train.

Nexus Turnkey Engineering Team

Written and reviewed by the engineers who design, install and maintain industrial air systems for Nexus Turnkey in Cambodia. Questions about this article? Ask us directly.

FAQ

Questions engineers ask us

What pressure dew point does a refrigerated dryer achieve?

The US DOE compressed air sourcebook gives about 35 to 39 °F, roughly +2 to +4 °C, for refrigerant-type dryers. Manufacturers commonly rate them at +3 °C pressure dew point at reference conditions, which corresponds to ISO 8573-1:2010 water Class 4. Real performance depends on inlet temperature, ambient temperature and load.

When do I need a desiccant dryer instead?

When the air, or any pipe it passes through, can be colder than a refrigerated dryer's dew point, or when the process requires drier air than Class 4. Examples include air lines through cold rooms, some pharmaceutical and electronics processes, and food applications where the guidance calls for a -40 °C pressure dew point.

Why does a desiccant dryer use compressed air?

A heatless desiccant dryer regenerates the saturated tower by passing some of the dried air back through it, called purge air. The DOE sourcebook gives purge requirements of 10 to 18 percent of the dryer's rating for pressure-swing types. Heated and heat-of-compression designs reduce or remove that purge, using heat instead.

Is drier air always better?

No. Drying beyond what the process needs costs energy and maintenance. The DOE advises drying only to the degree needed. Specify the ISO 8573-1 class each user actually requires, and consider point-of-use drying for the few users that need much drier air.

Next step

Turn this into a plan for your plant.

Send us your situation and an engineer will reply with the questions that matter and a sensible next step.