Pressure drop is the difference in pressure between two points in a system, caused by friction and restrictions. In compressed air it accumulates through treatment equipment, undersized mains, long hoses, quick couplings and clogged filters.
Every bar lost must be made up by generating at a higher pressure, which costs energy and increases leakage. The US Department of Energy notes that a well-designed system should lose well under 10% of the compressor’s discharge pressure before the point of use, and gives a rule of thumb of about 1% of compressor energy for every 2 psi (about 0.14 bar) of extra pressure, in the typical 100 psig range.
Practical note: measure ΔP across each filter and dryer, and from the compressor room to the farthest machine. Fix restrictions before raising the set point. Filter differential-pressure gauges are cheap indicators of when to change elements.