The element is only as good as its seal
A compressed air filter works only if all the air passes through the element. An element that fits the housing loosely, or a seal that has hardened, lets air bypass it, and a bypassing filter is worse than a loaded one because nobody knows it is not working. Replacement elements have to match the housing, not just the size.
What we supply
- Filter elements: particulate, coalescing and activated-carbon grades for the filters we supply, and matched elements for many installed housings, confirmed by make and model.
- Refrigerated dryer parts: drain service kits, filters, fans and controls, confirmed by dryer model.
- Desiccant dryer parts: valve service kits, exhaust silencers, pre-filter and after-filter elements, and desiccant.
When to change
- Coalescing elements are changed on schedule, usually at least annually, even if pressure drop looks acceptable, because efficiency can fall before pressure drop rises. Check the manufacturer’s recommendation.
- Particulate elements are changed on pressure drop or schedule, whichever comes first.
- Activated-carbon elements saturate without a pressure drop warning. They are changed on hours, or sooner if oil vapour or odour appears downstream.
- Desiccant is replaced when dew point can no longer be held after valve and filter service, or on the manufacturer’s schedule.
Tropical conditions
High condensate loads in the humid season stress drains and coalescers. Hot inlet air shortens desiccant life if pre-cooling is inadequate. Dusty compressor rooms load intake and line filters faster. We check these at each visit and adjust intervals to suit.
What Nexus provides
Element identification from housing and dryer details, supply on a planned schedule, element changes and dryer servicing under a maintenance contract, and dew-point and pressure-drop checks during visits. Send us the housing make, model and size, or a photo of the nameplate.