The electrical power a fixed-speed compressor still draws while running unloaded, delivering no compressed air.

When a load/unload screw compressor unloads, the motor keeps turning the airend against a closed inlet. It delivers no air but still draws a meaningful share of its full-load power. The Compressed Air Challenge uses 20-30% of full-load power as an estimating factor for unloaded rotary screws. Other published guides quote a wider 15-35%.

In a plant with several fixed-speed machines all part-loaded, unloaded hours can add up to a large slice of the electricity bill for no useful output.

Practical note: measure it, don’t assume it. A power logger on each compressor for a representative week shows loaded and unloaded hours directly. The usual fixes are a sequencer, a VSD trim machine and shorter unload timers where the motor’s start limits allow.