A membrane nitrogen generator feeds clean compressed air into thousands of hollow polymer fibres. “Fast” gases such as oxygen, water vapour and carbon dioxide permeate through the fibre walls and are vented; nitrogen-enriched air continues to the outlet.
Membranes have no moving parts and no switching valves, start quickly and are compact. Manufacturers typically quote purities around 95% to 99.5%, which suits tyre inflation, fire prevention and many blanketing duties. For higher purities, PSA is usually more efficient.
Practical note: purity and flow depend on feed pressure and temperature, so check performance at your real site conditions. As with PSA, oil and liquid water damage the fibres, so the feed needs coalescing and carbon filtration.